CC Products » CC Capture » Introduction to QuickChecker Interface
July 16, 2025

Introduction to QuickChecker Interface

Capture's QuickChecker interface offers a straightforward way to measure, compare, and track colors. The interface is designed to allow immediate reading in a scratchpad area and store master color reference tracking of colors in the ChromaChecker Cloud.  Measurement data can be displayed and stored in various ways to meet your production needs.

 

The key components of the QuickChecker Interface are:

Scratchpad    Inspector's Bar
Action Bar
Measurement Report
Compare Report      

 

ChromaChecker Capture - QuickChecker Interface

ChromaChecker Capture is a Mac/PC application designed for operators, and QuickChecker is one of the tools available within it. It's beneficial for handheld instruments.

Summary of Interface Elements:

 

 

 

 

Scratchpad

The Scratchpad (left side of the screen) provides a working space where all measurements from the last 24 hours are displayed. The measurement selected (highlighted with YELLOW) is presented in detail in the Measurement Report. On the right side of the measurement, the trash can icon enables permanent deletion - any measurement made incorrectly can be easily removed. All measurements on Scratchpad are deleted after 24 hours; if you want to save, then save to the library or job, or export CxF.

The Operator can select any measurement to see the related Measurement Report.

All measurements are auto-named, but the user can override the proposed name. The name of the color sample is supplemented with a serial number to facilitate navigation.

The "Substrate" and "Start Variation" functions create different types of data, with varying reports of measurement and names corresponding to the applied tool.

Important notes: 

Inspector's Bar

This is where the Operator selects which CC Capture Inspector they want to use.

Notes 

Action Bar

The operator selects what and how samples will be measured.

     Measure       Triggers regular measurement.  With most instruments, this button is the same as pushing the measure button on the Instrument.  
    Calibrate       Calibrate/Recalibrate button enables invoking the instrument calibration process on demand. It makes sense to initiate recalibration if a critical reference is about to be created.  
Start Variations This option allows a series of measurements of the same sample to quantify uniformity (homogeneity) and create spectrally averaged references learn more
     Substrate     If the measurement has to be evaluated in relation to the Substrate (density calculation, paper, textile, ...), the Substrate measurement should be made first.  learn more
         Clear        Some advanced features use previous measurements (Job ID, Customer, Project,...). This button is used to reset settings. Proper function when working with Projects  
Average checkbox This is an alternative method for creating averaged data. Using this option, only averaged data are sent to the server. No access to any individual measurements allowed  learn more
other options Some instruments have specific options -  they will be displayed here.  

 

Measurement Report - Setting (gray bar)

For more advanced tasks additional descriptions or color specification selections might be necessary for future analysis. Description fields are optional.

Color Specification Instruments can offer different M-conditions and other settings. Spectral to colorimetric value conversion requires Illuminant and Observer, and final values can be very different!     learn more
         Job ID            This description is optional. It can be used for filtering data by Job ID, which is required for Projects. Instead of manual input, a CC-2D barcode reader can be used to record JobID.   
learn more
       Customer         This description is optional. It may be used for filtering data by Customer, which can be useful. Instead of manually inputting, a CC-2D barcode reader can be used to capture customers.
    Sample Name     For regular measurements, QuickChecker is suggesting plain English names with sequential numbers. The Operator can change default name to any name. Using ChromaChecker Custom Instance, it is possible to use a custom auto-naming system.  

 

Important notes

Measurement Report - Result

The report uses the Color Specification setting to calculate colorimetric coordinates. If Instruments enable Multi-M-condition measurements (or function is enabled by the Operator) - once measured, the user can switch Color Specification and see how he numbers change per different M conditions. 

When the "Measure"  button is triggered, a typical report looks like this:

 

The detailed Measurement Report explanation is split into the following scenarios - select one to continue

Notes

Compare Report - Setup (gray bar)

 To compare the Sample, a Reference has to be selected. The following options are available:

These provide multiple sources for Reference data to compare against, many of the options provide a best match selection.

Compare Report Results

The following example uses the ChromaSpot Color Library as a reference.

 

Notes

Video

Related Topics

Contact ChromaChecker Support

Additional information and Support Form is available for logged users.

Peter · AI Assistant
Need help choosing the right path into ChromaChecker? I can guide you based on your role and workflow.